Detailed Inspection Report as of 12/26/2025 Print Report

Carrier Information

  • Creation Gardens Inc
  • 371005
  • 2055 Nelson Miller Parkway
    Louisville, KY 40223

Time/Location

  • GA1349001544
  • GA
  • GA
  • 10/7/2025
  • 1130
  • 1200
  • I. Full
  • Roadside
  • No
  • No

Vehicle Information

Unit Type Make Plate State Plate Number VIN
1 Straight Truck INTERNATIO GA YVU947 1HTKSSWM0PH511683

Carrier Violations

Vio Code Section Unit OOS Description Included in SMS BASIC Reason Not Included in SMS
393.19 393.19 1 No Inoperative/Defective Hazard Warning Lamp Yes Vehicle Maint.  
393.95A1 393.95(a)(1) 1 No Emergency Equipment - Fire Extinguishers - No Fire Extinguisher Present Or Not Properly Rated. Yes Vehicle Maint.  
393.95F 393.95(f) 1 No Emergency Equipment - Stopped Vehicle Warning Devices Missing Or Improper Yes Vehicle Maint.  
393.9A-LSLI 393.9(a) 1 No Lighting - Stop Lamps - Any Inoperative. Yes Vehicle Maint.  
393.9A-LTSI 393.9(a) 1 Yes Lighting - Turn Signal - Any Inoperative On The Rearmost Vehicle. Yes Vehicle Maint.