Detailed Inspection Report as of 12/26/2025
Carrier Information
- Graybar Electric Company Inc
- 128557
-
34 N Meramec Ave
St Louis, MO 63105
Time/Location
- NYD103001326
- NY
- NY
- 5/30/2025
- 0934
- 0954
- II. Walk-Around
- Fixed Site
- No
- No
Vehicle Information
| Unit | Type | Make | Plate State | Plate Number | VIN |
|---|---|---|---|---|---|
| 1 | Straight Truck | PETERBILT | NY | 48556MK | 2NP2HM6X3JM466967 |
Carrier Violations
| Vio Code | Section | Unit | OOS | Description | Included in SMS | BASIC | Reason Not Included in SMS |
|---|---|---|---|---|---|---|---|
| 393.48A-BMBCBD | 393.48(a) | 1 | No | Drum Brake - Missing/Broken Component(S) | Yes | Vehicle Maint. | |
| 393.9A-LLPL | 393.9(a) | 1 | No | Lighting - License Plate Lamp Inoperative | Yes | Vehicle Maint. | |
| 396.3A1-BOS | 396.3(a)(1) | 1 | Yes | Brake - Defective Brake(S) Are Equal To Or Greater Than 20% Of The Service Brakes On The Vehicle/Combination | Yes | Vehicle Maint. |