Detailed Inspection Report as of 12/26/2025
Carrier Information
- Graybar Electric Company Inc
- 128557
-
34 N Meramec Ave
St Louis, MO 63105
Time/Location
- OH3275013932
- OH
- OH
- 8/30/2024
- 0835
- 0920
- I. Full
- Roadside
- No
- No
Vehicle Information
| Unit | Type | Make | Plate State | Plate Number | VIN |
|---|---|---|---|---|---|
| 1 | Straight Truck | PTRB | PA | ZRW0676 | 2NP2HM6X1NM777867 |
Carrier Violations
| Vio Code | Section | Unit | OOS | Description | Included in SMS | BASIC | Reason Not Included in SMS |
|---|---|---|---|---|---|---|---|
| 393.47E | 393.47(e) | 1 | No | Brake Out Of Adjustment - Roto, Clamp (Short & Long), Dd-3, Or Bolt | Yes | Vehicle Maint. | |
| 393.53B | 393.53(b) | 1 | No | Cmv Manufactured After 10/19/94 Has An Automatic Airbrake Adjustment System That Fails To Compensate For Wear | Yes | Vehicle Maint. | |
| 396.3A1BOS | 396.3(a)(1) | 1 | Yes | Brakes Out Of Service: The Number Of Defective Brakes Is Equal To Or Greater Than 20 Percent Of The Service Brakes On The Vehicle Or Combination | Yes | Vehicle Maint. |