Detailed Inspection Report as of 1/30/2026
Carrier Information
- Pavestone Llc
- 337319
-
5 Concourse Parkway Suite 1900
Atlanta, GA 30328
Time/Location
- ORAP43220068
- OR
- OR
- 8/1/2024
- 0912
- 1006
- I. Full
- Fixed Site
- No
- No
Vehicle Information
| Unit | Type | Make | Plate State | Plate Number | VIN |
|---|---|---|---|---|---|
| 1 | Straight Truck | INTERNATIO | OR | YASG841 | 1HTGLAET1YH315730 |
| 2 | Full Trailer | PEERLESS D | OR | HP22594 | 1PLF02038HTH85820 |
Carrier Violations
| Vio Code | Section | Unit | OOS | Description | Included in SMS | BASIC | Reason Not Included in SMS |
|---|---|---|---|---|---|---|---|
| 393.45D-B | 393.45(d) | 1 | No | Air Brake - Audible Air Leak At A Proper Connection | Yes | Vehicle Maint. | |
| 393.47E | 393.47(e) | 2 | No | Brake Out Of Adjustment - Roto, Clamp (Short & Long), Dd-3, Or Bolt | No | Multiple Cites | |
| 393.47E | 393.47(e) | 2 | No | Brake Out Of Adjustment - Roto, Clamp (Short & Long), Dd-3, Or Bolt | Yes | Vehicle Maint. | |
| 393.9A-LSLI | 393.9(a) | 1 | No | Lighting - Stop Lamps - Any Inoperative. | Yes | Vehicle Maint. | |
| 393.9A-LSLIWR | 393.9(a) | 2 | Yes | Lighting - Stop Lamps - Both Inoperative When Required To Be On | Yes | Vehicle Maint. | |
| 396.3A1-BALR | 396.3(a)(1) | 1 | Yes | Air Brake - Fails Air Loss Rate Test | Yes | Vehicle Maint. |