Detailed Inspection Report as of 7/31/2026 Print Report

Carrier Information

  • Eco Transportes Internacionales Sa De Cv
  • 558117
  • Manuel J Clouthier N 1018
    Cd Juarez, CI 32550

Time/Location

  • TXV241221148
  • TX
  • TX
  • 4/3/2024
  • 1140
  • 1301
  • I. Full
  • Roadside
  • No
  • Yes

Vehicle Information

Unit Type Make Plate State Plate Number VIN
1 Truck Tractor INTL MX 38ER7M 1HSHXAHR46J302733
2 Semi-Trailer STRI MX 352WE1 1S12E9532SE389497

Carrier Violations

Vio Code Section Unit OOS Description Included in SMS BASIC Reason Not Included in SMS
172.201A1 172.201(a)(1) 1 No Hazardous Materials Not Distinguished From Non-Hazardous Materials No   Not used in SMS Calculation
172.201D 172.201(d) 1 No Er Phone Number Not In Compliance With Subpart G No   Not used in SMS Calculation
393.11 393.11 1 No No Or Defective Lighting Devices Or Reflective Material As Required No   Multiple Cites
393.11 393.11 2 No No Or Defective Lighting Devices Or Reflective Material As Required No   Multiple Cites
393.11S 393.11 2 No Side Retroreflective Sheeting Or Reflex Reflector Requirements For Vehicles Manufactured After December 1993 No   Not used in SMS Calculation
393.45 393.45 1 Yes Brake Tubing And Hose Adequacy No   Not used in SMS Calculation
393.45B2PC 393.45(b)(2) 1 No Brake Hose Or Tubing Chafing And/Or Kinking - Connection To Power Unit No   Not used in SMS Calculation
393.45B2UV 393.45(b)(2) 2 No Brake Hose Or Tubing Chafing And/Or Kinking Under Vehicle No   Multiple Cites
393.45B2UV 393.45(b)(2) 2 No Brake Hose Or Tubing Chafing And/Or Kinking Under Vehicle No   Multiple Cites
393.45DCUV 393.45(d) 1 No Brake Connections With Constrictions Under Vehicle No   Not used in SMS Calculation
393.9 393.9(a) 1 No Inoperable Required Lamp No   Not used in SMS Calculation
393.95B 393.95(b) 1 No Emergency Equipment - A Power Unit Requiring Fuses - Missing A Spare Fuse For A Required Part Or Accessory (E.G., Lamps Required By 393.11, Abs Lights Or Low Air No   Not used in SMS Calculation
396.3A1 396.3(a)(1) 1 No Inspection, Repair And Maintenance Of Parts And Accessories No   Not used in SMS Calculation

Hazardous Material

HazMat Code HazMat Description Reported Quantity Waste Status
9 9 MISCELLANEOUS HM No Yes A
3 3 FLAMMABLE No Yes A