| 172.328(d) |
Fail to mark manual remote shutoff device with "Emergency Shutoff" |
5 |
0 |
5 |
| 177.817(e) |
Shipping paper accessibility |
5 |
0 |
3 |
| 172.516C6-HMPMC |
HM (Placarding) - Failure to maintain placard(s) in a condition so that the format, legibility, color, and visibility of the placard will not be substantially reduced due to damage, deterioration, or obscurement by dirt or other matter. |
4 |
0 |
5 |
| 172.328D-HMM |
HM (Markings) - Failing to mark a manual remote shut-off device as required. |
3 |
0 |
3 |
| 172.516(c)(6) |
Placard damaged, deteriorated, or obscured |
3 |
0 |
5 |
| 172.602A-HMER |
HM (Emergency Response) - No emergency response information. |
3 |
0 |
3 |
| 172.600C1-HMER |
HM (Emergency Response) - No emergency response information immediately available. |
2 |
0 |
3 |
| 173.24(b)(1) |
Release of Hazardous Materials from package |
2 |
2 |
10 |
| 177.801-HMHCNP |
HM (Highway Carriage) - Driver accepted/transported HM not prepared in accordance with this Subchapter. Explain: |
2 |
0 |
2 |
| 177.823(a) |
No placards/markings when required |
2 |
1 |
5 |
| 177.823A-HMPMCM |
HM (Placarding) - A carrier may not move a transport vehicle containing a hazardous material unless the vehicle is marked and placarded in accordance with part 172 or as authorized in §171.12a of this subchapter, or unless, in an emergency. |
2 |
0 |
5 |
| 177.823A-HMPMCNP50% |
HM (Placarding) - 50% or more of the required placards for a hazard class are missing. CVSA Inspection Bulletin 2017-03 - Display of GHS Labels on Bulk Packages. |
2 |
2 |
5 |
| 177.823A-HMTVMMCNID |
HM (Transport Vehicle Markings) - 50% or more of the required ID numbers are missing for each material. |
2 |
2 |
5 |
| 177.823A-HMTVMNID |
HM (Transport Vehicle Markings) - Less than 50% of the required ID numbers are missing for each material. |
2 |
0 |
5 |
| 177.834J1-HMBPMC |
HM (Bulk Packages) - Missing or imporperly secured manhole covers. NOTE: An OOS condition exists when any of the manhole cover's securement devices are missing or unsecured. |
2 |
2 |
4 |
| 397.67 |
HM vehicle routing violation (non RAM) |
2 |
0 |
1 |
| 172.200(a) |
No shipping paper provided by offeror |
1 |
1 |
3 |
| 172.201D-HMSPS |
HM (Shipping Papers) - Shipper HM shipping paper does not list emergency response telephone number as required. |
1 |
0 |
3 |
| 172.202A1-HMSPS |
HM (Shipping Papers) - Shipper HM shipping paper does not list ID number as required. |
1 |
0 |
3 |
| 172.202A2-HMSPS |
HM (Shipping Papers) - Shipper HM shipping paper does not list proper shipping name as required. |
1 |
0 |
3 |
| 172.202A3-HMSPS |
HM (Shipping Papers) - Shipper HM shipping paper does not list hazard class or division number as required. |
1 |
0 |
3 |
| 172.202B-HMSPS |
HM (Shipping Papers) - Shipper HM shipping paper does not list basic description in proper sequence as required. |
1 |
0 |
3 |
| 172.502(a)(1) |
Prohibited placarding |
1 |
0 |
5 |
| 172.504A-HMPS |
HM (Placarding) - Bulk package/freight container/unit load device/transport vehicle not placarded as required. |
1 |
0 |
5 |
| 172.516(c)(1) |
Placard not securely affixed or attached |
1 |
0 |
5 |
| 172.516C2-HMPMC |
HM (Placarding) - Failure to display placard(s) clear of appurtenances. |
1 |
0 |
5 |
| 172.519 |
Placard does not meet specifications |
1 |
0 |
5 |
| 172.600(c) |
Offer or transport without emergency response information |
1 |
0 |
3 |
| 172.602(a) |
Emergency Response information not complete |
1 |
0 |
3 |
| 172.602(b) |
Form and manner of Emergency Response information |
1 |
0 |
3 |
| 172.602(c)(1) |
Maintenance/accessibility of Emergency Response information |
1 |
0 |
3 |
| 172.602C-HMER |
HM (Emergency Response) - Improper maintenance/accessibility of emergency response information. |
1 |
0 |
3 |
| 172.606B2-HMER |
HM (Emergency Response) - Failing to have the shipping paper and emergency response information readily available on the tranport vehicle. |
1 |
0 |
3 |
| 173.24B1-HMBPMC |
HM (Bulk Packages) - HM/DG leaking from a bulk package (including associated piping). |
1 |
1 |
10 |
| 173.24C-HMGP |
HM (General Packaging) - Using an unauthorized non-bulk packaging for the transportation of HM. |
1 |
0 |
10 |
| 177.804(a) |
Failure to comply with FMCSR 49 CFR Parts 390 through 397 When Transporting HM |
1 |
0 |
2 |
| 177.817A-HMPSPMC |
HM (Shipping Papers) - Motor carrier permit/require a driver to operate a motor vehicle without a proper shipping paper. |
1 |
0 |
3 |
| 177.817A-HMSP |
HM (Shipping Papers) - Operate a motor vehicle without a required shipping paper. NOTE: An error in the shipping description or an incomlete shipping description that will not impede emergency response does not constitute an OOS condition. |
1 |
1 |
3 |
| 177.817E2-HMHC |
HM (Highway Carriage) - Failing to have HM shipping papers readily accessible. |
1 |
0 |
3 |
| 177.823A-HMPMCNP |
HM (Placarding) - Any placard(s) misrepresent(s) the HM/DG being transported. CVSA Inspection Bulletin 2017-03 - Display of GHS Labels on Bulk Packages. |
1 |
1 |
5 |
| 177.834(j) |
Manholes and valves not closed or leak free |
1 |
1 |
4 |
| 177.834J2-HMBP |
HM (Bulk Packages) - Operate a motor vehicle with the internal valve in the open position. |
1 |
1 |
4 |
| 177801LEAK |
Accepting/transporting HM not prepared in accordance with the regulations. Package has identifiable (without the use of instruments) release of HM to the environment. |
1 |
1 |
2 |
| 178.340-6 |
MC306/307/312 supports and anchoring |
1 |
0 |
8 |
| 178.345-5-HMP |
HM (Packaging) - DOT 406/407/412 manhole requirements. |
1 |
0 |
8 |
| 178.345-6-HMP |
HM (Packaging) - DOT 406/407/412 supports and anchoring requirements. |
1 |
0 |
8 |
| 178.345-8A5-HMP |
HM (Packaging) - DOT 406/407/412 minimum road clearance. |
1 |
0 |
8 |
| 180.415-HMTMC |
HM (Testing) - Failing to properly mark cargo tank test dates as required. |
1 |
0 |
7 |
| 385.403-HMAMC |
HM (Administrative) - Motor Carrier failing to obtain an HM safety permit as required. |
1 |
0 |
3 |
| 397.67B-HMDP |
HM (Driving & Parking) - Operate an HM motor vehicle, reqruied to be placarded or marked in violation of routing (Non RAM). |
1 |
0 |
1 |